Frequently asked questions
Electrical safety
Warning signs, what to do about them, and what is worth worrying about.
Treat it as urgent. Stop using the affected circuit and, if it is safe to do so, switch it off at the consumer unit. A burning smell around electrical equipment usually means a connection is overheating, and overheating connections are a fire risk. Do not wait to see whether it happens again — get it looked at.
A socket should not be noticeably warm. Slight warmth on a socket supplying a heavy load can be normal; warmth on a lightly loaded socket, or any discolouration around the pins, suggests a poor connection. Poor connections generate heat, and heat is how electrical fires start.
Yes. A shock from an appliance or a fitting means current is going somewhere it should not, and it should not be dismissed because it was mild. Stop using the item, isolate the circuit if you can, and have it investigated. Where there is no RCD protection on that circuit, it matters more still.
General guidance in the UK is up to ten years for an owner-occupied home, up to five years for rented domestic property or at each change of tenancy, and typically five years for commercial premises — though the interval depends on the building and its use. If you do not know when yours was last inspected, that is itself a reason to have it looked at.
An Electrical Installation Condition Report is a formal inspection and test of a fixed electrical installation. It records the condition of the installation and lists observations with codes indicating how urgently each needs attention. It is a snapshot of condition, not a certificate for new work.
Broadly: C1 means danger is present and immediate action is required; C2 means potentially dangerous and urgent remedial action is required; C3 means improvement is recommended but the installation is not unsafe; and FI means further investigation is needed. C1 and C2 observations make a report unsatisfactory.
The C1 and C2 observations need addressing to bring the installation to a satisfactory condition. C3 items are recommendations rather than requirements. We carry out remedial work arising from inspection reports — send us the report and we will work through what it actually calls for.
Round-pin sockets indicate wiring that is likely to be very old — often pre-1960s. That does not automatically make it dangerous, but an installation of that vintage will almost certainly not meet current standards and should be inspected and tested before any conclusion is drawn about it.
Extension leads are designed as a temporary solution. Used permanently, particularly for high-load appliances such as heaters, they carry a real risk of overheating — and daisy-chaining them multiplies it. If you are relying on one permanently, the honest answer is that the room needs another socket.
RCD protection disconnects the supply when current leaks to earth, which is the fault that matters when a person is involved. Modern installations have it as standard. If your board has none, adding it is usually the single most useful safety improvement available to you.
An RCD detects earth leakage but does not protect against overload. An RCBO combines both in one device, per circuit. The practical difference is that with RCBOs, a fault on one circuit only disconnects that circuit — with a shared RCD, it takes out everything on that side of the board.
Certain work in dwellings in England and Wales is notifiable under the Building Regulations and must be carried out and certified appropriately. Beyond the legal position, work on a fixed installation carries a genuine risk of serious injury and fire. We would not encourage it.
If there is fire, smoke or anyone is injured, call the emergency services. Otherwise, isolate the affected circuit at the consumer unit if you can do so safely, stop using it, and arrange for it to be investigated. Do not attempt to repair a circuit you have isolated because of a fault.
They can be. Mains-powered interlinked smoke alarms are part of the fixed installation and need testing and periodic replacement — most units have a stated lifespan of around ten years regardless of whether they still respond to a test. Battery-only alarms are separate but no less important.
Call us
Speak to an electrician
Describe the fault or the job and we will tell you what is involved.
Keep exploring
Where to next
- All electrical services Installation, repairs, CCTV, fire alarms, lighting, EV charging and consumer units.
- Areas we cover Thirty-three London boroughs, each with its own page.
- Guides and advice Fifty practical articles for homeowners, landlords and businesses.
- Project gallery Examples of the work, by type.