Frequently asked questions
Electrical questions, answered
Straight answers to the questions we are asked most often — about installations, repairs, consumer units, CCTV, fire alarms, lighting, EV charging and electrical safety.
Getting started
Call 07832450917, email info@beydillibright.com, or send an enquiry through the contact page. Tell us what the property is, what needs doing and roughly when you are hoping to have the work carried out. Some jobs can be priced from that description; others need looking at first, and we will say which yours is.
That depends on the job, and we will tell you before arranging anything. A quick look at a consumer unit is different from a detailed survey of a commercial installation. What we will not do is turn up and present a charge you were not expecting.
The property type and rough age, what is happening or what you are planning, and where the consumer unit is. A photograph of the board is genuinely useful and often tells us more than a description. For commercial premises, the trading hours and any access restrictions matter from the first conversation.
For some jobs, yes — a straightforward, well-described piece of work in a property with no complications can be priced from a conversation. For anything where the existing installation affects the answer, a phone quote would be a guess, and a guess that changes later is worse than no quote at all.
It varies with the size of the job and what is already scheduled. Tell us your timescale when you enquire and we will be straight with you about whether it is achievable. We do not publish response times we cannot consistently meet.
Yes. A lot of our domestic work is remedial work following Electrical Installation Condition Reports, consumer unit replacement between tenancies, and repairs in let property. Working through a report's observations systematically is usually quicker and cheaper than addressing them one at a time.
Yes. On refurbishment and extension projects it helps considerably to be involved before first fix, because the electrical requirement often affects decisions that are expensive to revisit — particularly whether the existing consumer unit can take the new circuits.
Yes. Electrical work in an occupied property generates dust and debris, and clearing it is part of the job rather than an extra. Where work involves chasing walls or lifting floors, we will explain beforehand what the disruption will actually look like.
We go through what has been done, show you anything you need to know — where circuits are, what has been labelled, how new equipment works — and hand over the documentation relating to the work.
Often, yes, particularly for light fittings where the choice is an aesthetic one. It is worth checking compatibility with us first — dimmable LED fittings especially, where the wrong driver and dimmer combination causes flicker that no amount of installation care will fix.
We are based at 46 Bradley Road in Enfield and work across London and the surrounding areas. The areas page lists the boroughs we have written pages for, but that list reflects our published content rather than the limit of where we work — if your postcode is not listed, call and ask.
BeydilliBright Ltd. is owned and run by Özer Beydilli. You are dealing with the business directly rather than through a lead-generation site that sells your enquiry on to whoever is available.
Electrical safety
Treat it as urgent. Stop using the affected circuit and, if it is safe to do so, switch it off at the consumer unit. A burning smell around electrical equipment usually means a connection is overheating, and overheating connections are a fire risk. Do not wait to see whether it happens again — get it looked at.
A socket should not be noticeably warm. Slight warmth on a socket supplying a heavy load can be normal; warmth on a lightly loaded socket, or any discolouration around the pins, suggests a poor connection. Poor connections generate heat, and heat is how electrical fires start.
Yes. A shock from an appliance or a fitting means current is going somewhere it should not, and it should not be dismissed because it was mild. Stop using the item, isolate the circuit if you can, and have it investigated. Where there is no RCD protection on that circuit, it matters more still.
General guidance in the UK is up to ten years for an owner-occupied home, up to five years for rented domestic property or at each change of tenancy, and typically five years for commercial premises — though the interval depends on the building and its use. If you do not know when yours was last inspected, that is itself a reason to have it looked at.
An Electrical Installation Condition Report is a formal inspection and test of a fixed electrical installation. It records the condition of the installation and lists observations with codes indicating how urgently each needs attention. It is a snapshot of condition, not a certificate for new work.
Broadly: C1 means danger is present and immediate action is required; C2 means potentially dangerous and urgent remedial action is required; C3 means improvement is recommended but the installation is not unsafe; and FI means further investigation is needed. C1 and C2 observations make a report unsatisfactory.
The C1 and C2 observations need addressing to bring the installation to a satisfactory condition. C3 items are recommendations rather than requirements. We carry out remedial work arising from inspection reports — send us the report and we will work through what it actually calls for.
Round-pin sockets indicate wiring that is likely to be very old — often pre-1960s. That does not automatically make it dangerous, but an installation of that vintage will almost certainly not meet current standards and should be inspected and tested before any conclusion is drawn about it.
Extension leads are designed as a temporary solution. Used permanently, particularly for high-load appliances such as heaters, they carry a real risk of overheating — and daisy-chaining them multiplies it. If you are relying on one permanently, the honest answer is that the room needs another socket.
RCD protection disconnects the supply when current leaks to earth, which is the fault that matters when a person is involved. Modern installations have it as standard. If your board has none, adding it is usually the single most useful safety improvement available to you.
An RCD detects earth leakage but does not protect against overload. An RCBO combines both in one device, per circuit. The practical difference is that with RCBOs, a fault on one circuit only disconnects that circuit — with a shared RCD, it takes out everything on that side of the board.
Certain work in dwellings in England and Wales is notifiable under the Building Regulations and must be carried out and certified appropriately. Beyond the legal position, work on a fixed installation carries a genuine risk of serious injury and fire. We would not encourage it.
If there is fire, smoke or anyone is injured, call the emergency services. Otherwise, isolate the affected circuit at the consumer unit if you can do so safely, stop using it, and arrange for it to be investigated. Do not attempt to repair a circuit you have isolated because of a fault.
They can be. Mains-powered interlinked smoke alarms are part of the fixed installation and need testing and periodic replacement — most units have a stated lifespan of around ten years regardless of whether they still respond to a test. Battery-only alarms are separate but no less important.
Consumer units and fuse boxes
They are the same thing. "Fuse box" is the everyday term and "consumer unit" is the technical one. Both describe the board where the incoming supply is divided into circuits and protected. What has changed over the decades is how much protection that involves.
Rewirable fuses rather than circuit breakers, a wooden back box, no RCD protection at all, repeated unexplained tripping, any sign of heat damage or discolouration, no spare ways when you need to add a circuit, or an inspection report with observations about the board. Any of those is worth a conversation.
No. Age alone does not make a board unsafe, and replacing one in sound condition purely because it is old is not always necessary. What matters is its condition, the protection it provides and the state of the installation behind it. That is an assessment, not a rule of thumb.
Typically a day for a straightforward domestic board, including the testing before and after. It takes longer where circuits need tracing, where faults are found during the pre-replacement testing, or where the board is being relocated. We would rather give you a realistic figure than an optimistic one.
Because a new board with sensitive RCD protection will immediately reveal faults that an old board tolerated silently — most often deteriorated insulation in older wiring. Finding those first is what prevents the situation where a brand new consumer unit will not stay switched on.
Yes, for most of it. The supply has to be isolated while circuits are transferred to the new board. We will tell you in advance roughly how long that will be so you can plan around it — particularly important if you work from home or have anything that cannot lose power.
Often, yes. Boards in under-stairs cupboards or awkward corners are common in older property, and relocation is worth considering if the board is being replaced anyway. It adds work, because the tails and every circuit have to reach the new position, so it is a decision to make at the outset.
Yes. Consumer unit replacement in a dwelling in England and Wales is notifiable under the Building Regulations, and the installation must be certified. [INSERT INFORMATION] — the company's competent person scheme registration should be confirmed and stated here.
Sometimes, with a smaller board added alongside for the new circuit. Whether that is the sensible answer depends on the age and condition of the existing board — if it was heading for replacement anyway, doing it once is usually better than doing it twice.
An SPD limits voltage spikes reaching the installation, typically from lightning activity or supply switching. Whether one is required depends on the property and the risk assessment. They are more commonly fitted now than they once were, particularly where there is expensive connected equipment.
Consumer units in domestic premises are now generally required to have a non-combustible enclosure, which in practice means metal. This followed a pattern of fires originating in plastic boards. An existing compliant plastic board does not have to be replaced solely for that reason.
Domestic electrical work
The reliable indicators are test results rather than appearance. Widespread low insulation resistance readings, rubber or fabric-insulated cable, and an installation that has reached the end of its serviceable life all point that way. Age alone does not — plenty of sixty-year-old installations test perfectly well.
Related: Domestic Electrical Services
Genuinely disruptive. A full rewire means lifting floors, chasing walls and redecoration afterwards, and in an occupied house it is hard going. That is exactly why partial rewiring — a floor, a kitchen, or a specific set of circuits — is far more common and often the sensible answer.
Related: Domestic Electrical Services
Usually yes, working room by room or floor by floor, but it is not comfortable. If the property is empty — between tenancies, before moving in, or during a wider refurbishment — the work is faster, cheaper and considerably less painful.
Related: Domestic Electrical Services
There is no fixed number, but the honest test is whether you are using extension leads. If you are, the room needs more sockets. It is worth thinking about where furniture actually sits rather than where sockets conventionally go — behind a sofa is the least useful position in the room.
Related: Domestic Electrical Services
Sometimes. Where a socket can be fed from an adjacent one, or from below through a floor void, the damage can be minimal. Where a cable has to be chased into a wall, some making good is unavoidable. We will tell you which applies before starting.
Related: Domestic Electrical Services
Yes. An outbuilding supply is a designed circuit with appropriate protection and, where it runs underground, the correct cable at the correct depth. It is not a job for an extension lead across the lawn — that arrangement is both unsafe and, in wet weather, actively hazardous.
Related: Domestic Electrical Services
Almost always. Kitchens concentrate high-load appliances, and a refit usually involves moving sockets, adding circuits for ovens or hobs, and reworking lighting. Kitchen electrical work also falls within the scope of notifiable work in some circumstances, so it is not an area for improvisation.
Related: Domestic Electrical Services
New lighting and sockets in the converted space, usually a new circuit or two back to the board, smoke detection to meet the fire strategy for the altered layout, and frequently board work because the existing consumer unit has no spare ways. The last of those is the one that catches people out.
Related: Domestic Electrical Services
Within the flat itself, generally yes. The complications in flats are cable routes — party walls and shared floors limit where cable can go — and anything involving communal areas or risers, which normally needs the freeholder's or managing agent's agreement.
Related: Domestic Electrical Services
Bathrooms have specific requirements because of the presence of water: zones determine what equipment may be installed where, fittings need appropriate ingress protection ratings, and supplementary bonding may be required. It is one of the areas where the rules are strictest, and for good reason.
Related: Domestic Electrical Services
Yes. An electric shower needs its own high-current circuit from the board with appropriate protection and a suitably rated isolator. The question that decides the job is usually whether the consumer unit has a spare way and whether the supply comfortably supports the additional load.
Related: Domestic Electrical Services
Yes, and the first task is almost always establishing how the supply is actually divided between the dwellings — which board serves what, and where the boundary with the communal installation sits. In older conversions this is frequently undocumented, and board work without knowing it is guesswork.
Related: Domestic Electrical Services
Yes. Buyers' surveys frequently flag electrical items, and addressing them before or during a sale is common. An inspection first establishes what actually needs doing, rather than reacting to a survey comment that may be more cautious than the installation warrants.
Related: Domestic Electrical Services
Commercial electrical work
Yes, and for most commercial premises that is the only practical arrangement. Tell us your trading hours and any access constraints at the first conversation, because they shape the programme rather than being fitted around it afterwards.
Related: Commercial Electrical Services
Typically every five years, though the interval depends on the type of premises, how they are used and what any previous report recommended. Higher-risk environments need more frequent inspection. Your insurer may also have requirements.
Related: Commercial Electrical Services
Scheduled visits to inspect and test the installation, check terminations and connections, and address anything showing early signs of trouble. Loose terminations and overheating connections give warning long before they fail — planned maintenance is simply arranging for somebody to look.
Related: Commercial Electrical Services
Commonly an overloaded circuit, a deteriorating connection, or a fault causing repeated protective device operation. In commercial premises it is also frequently a circuit that was adequate for the original use and is not adequate for the current one. It needs tracing rather than resetting.
Related: Commercial Electrical Services
Usually, but the first question is whether the supply and distribution can take it. Adding significant load to an installation already near capacity is the most common way a straightforward job becomes an expensive one — and much better discovered at planning stage than at commissioning.
Related: Commercial Electrical Services
Yes — power, display lighting, signage supplies, till and card terminal circuits, and the coordination with other trades that a fit-out involves. Retail fit-outs almost always run to a fixed opening date, so the programme matters as much as the work.
Related: Commercial Electrical Services
Three-phase supplies deliver more power and suit equipment with high demand — machinery, large HVAC plant, some commercial catering. Many commercial units already have it from a previous occupier. Whether you need it depends entirely on your equipment, and it is worth checking what is already there.
Related: Commercial Electrical Services
Yes. Emergency lighting is required in most commercial premises, needs periodic testing, and the results need recording. Where a layout changes, the emergency lighting usually needs revisiting too — escape routes that have moved are a common gap after a refurbishment.
Related: Commercial Electrical Services
Portable appliance testing covers equipment that plugs in, which is separate from the fixed installation. [INSERT INFORMATION] — confirm whether the business offers in-service inspection and testing of portable equipment.
Related: Commercial Electrical Services
Power where people will actually sit, which usually means floor boxes or desk power rather than wall sockets; comms provision; lighting that suits the new layout rather than the old one; and emergency lighting reviewed against the changed escape routes. Planning these together is much cheaper than retrofitting.
Related: Commercial Electrical Services
Yes. For managed property and multi-site businesses, a scheduled programme across sites is more practical than reactive call-outs, and it produces the records that insurers and inspections ask for. Tell us how many sites and what they are, and we will propose an approach.
Related: Commercial Electrical Services
Faults and repairs
Three common causes: an overloaded circuit, a short circuit, or earth leakage. A breaker that trips once and resets cleanly may have been a one-off — an appliance failing, for instance. One that trips repeatedly is reporting a fault, and resetting it repeatedly is not a fix.
Related: Electrical Services
Unplug everything on the affected circuits, reset the RCD, then reconnect items one at a time, leaving a gap between each. If it trips when a particular appliance is reconnected, that appliance is the likely culprit. If it trips with nothing connected, the fault is in the fixed wiring and needs investigating.
Related: Electrical Services
With LED fittings, most often a dimmer and driver that are not compatible. Otherwise, a loose connection somewhere in the lighting circuit — which is worth taking seriously, because loose connections generate heat. Flickering across the whole property rather than one circuit can indicate a supply issue.
Related: Electrical Services
Often, yes — a failed accessory or a loose connection at that point. But a dead socket can also be the visible end of a fault further back in the circuit, particularly on older ring circuits. Testing establishes which, and that determines the job.
Related: Electrical Services
Fault finding is the diagnostic work of locating a fault: isolating circuits, testing insulation resistance and continuity, and narrowing down methodically. It is skilled work that takes time and is genuinely separate from the repair, because until the fault is found nobody knows what the repair is.
Related: Electrical Services
Yes, but intermittent faults take longer. The pattern is the useful clue — whether it happens in wet weather, at a particular time, or when a specific appliance runs. Keep a note of when it trips before we visit; it frequently narrows the search considerably.
Related: Electrical Services
Look at the consumer unit: an RCD covering one side of the board will take out several circuits at once. If it will not reset, there is a fault on one of those circuits. Also check whether neighbours have power — if not, it is a supply issue rather than your installation.
Related: Electrical Services
A wider outage is the responsibility of the distribution network operator, not an electrician. In Great Britain you can call 105 free from most phones and be connected to the relevant network operator for your area.
Related: Electrical Services
Repeated early failures in the same fitting usually point to a problem with the fitting or the connection rather than the bulbs. Heat is a common factor — enclosed fittings shorten LED life considerably. Failures across the whole property can indicate a supply voltage issue.
Related: Electrical Services
No. A consumer unit should be silent. Buzzing or humming can indicate a loose connection or a device that is failing, and both deserve prompt attention. Do not ignore it because everything still works — connections that generate heat are exactly how electrical fires begin.
Related: Electrical Services
Water and electricity need separating before anything else happens. Isolate the affected circuits, deal with the water, and let things dry before testing. Accessories and cable that have been wet frequently need replacing rather than drying out — testing establishes what survived.
Related: Electrical Services
Yes, and it is common. Where we find work that does not meet standards, we will tell you what is wrong and what it would take to put right. We will not, however, certify somebody else's installation as though we had carried it out.
Related: Electrical Services
CCTV and security
Fewer than most people expect, positioned better than most systems are. Four well-placed cameras will tell you more than twelve installed without a plan. The number follows from what you need to see — identification at entry points is a different requirement from general area coverage.
Related: CCTV Installation
At the points where someone actually approaches, at a height where a face is captured rather than the top of a head. Mounting cameras high and looking down is common and produces footage in which nobody can be identified — which defeats the purpose of having them.
Related: CCTV Installation
For a permanent installation, wired is generally more reliable: no dependency on wireless signal quality, and power and data in one run. Wireless has its place where cabling is genuinely impractical, but it introduces failure modes a hard-wired system does not have.
Related: CCTV Installation
Only as long as there is a reason to keep it. Retention should be proportionate to the purpose — commonly a few weeks for general security. Keeping footage indefinitely creates a data protection liability without adding much practical benefit.
Related: CCTV Installation
Yes, remote viewing is standard on modern systems. The thing worth insisting on is that the default password is changed during setup — unchanged default credentials are the single most common weakness in domestic and small commercial CCTV, and remotely accessible cameras are actively scanned for.
Related: CCTV Installation
If your system captures areas beyond your own property boundary, data protection obligations apply and signage is part of that. For commercial premises the requirements go further. We will flag where this is likely to apply, but you should take your own advice on compliance.
Related: CCTV Installation
It can, but doing so brings your system within UK GDPR, with obligations including signage and responding to requests for footage. On terraced and semi-detached streets this comes up more often than people expect, and it is worth taking into account when positioning cameras.
Related: CCTV Installation
Frequently, yes, and existing cable routes can often be reused — which keeps both disruption and cost well below a fresh installation. Where a system is old enough that the cabling itself is the limitation, we will tell you rather than fitting new cameras onto infrastructure that cannot support them.
Related: CCTV Installation
Modern cameras handle low light well, but "works at night" varies enormously with the position. Infrared illumination has a limited effective range, and a camera pointing towards a bright light source will struggle regardless of specification. Night performance is a positioning question as much as a camera one.
Related: CCTV Installation
At least annually. Cameras drift out of alignment, lenses get dirty, seals degrade and hard drives fail — usually silently. A system nobody has checked for two years is quite often not recording at all, which is discovered at precisely the wrong moment.
Related: CCTV Installation
The recorder needs a supply, and cameras are typically powered over the same cable that carries their data. The practical considerations are where the recorder lives, whether it is somewhere secure, and whether it is protected against losing power at the moment it matters.
Related: CCTV Installation
Fire alarm systems
That should come from the fire risk assessment for the building, which considers its layout, use and occupants. Specifying a system without one is guesswork. If you do not have a current assessment, that is the place to start rather than the system.
Related: Fire Alarm Systems
A conventional system tells you which zone has activated; an addressable system tells you which device. In a larger building that difference matters a great deal, because locating the activation quickly is the whole point. Conventional systems remain appropriate in smaller premises.
Related: Fire Alarm Systems
Weekly testing of a call point is normal practice, with professional servicing at defined intervals and records kept of both. In commercial premises this is part of the responsible person's duties, not an optional maintenance item.
Related: Fire Alarm Systems
Most often the wrong detector type in the wrong place — smoke detection near a kitchen, a bathroom, a dusty area or somewhere with steam. It is a solvable problem, and worth solving: premises that have had repeated false alarms are premises where people stop evacuating.
Related: Fire Alarm Systems
Yes. We will inspect the existing system, test the devices and the panel, and record the results. If we find the system is not adequate for the building as it is now used, we will say so — that is information you need, even when it is not what you wanted to hear.
Related: Fire Alarm Systems
Requirements depend on the building. Individual dwellings typically need interlinked smoke and heat detection; blocks of flats and houses in multiple occupation have additional requirements driven by their layout and fire strategy. The fire risk assessment determines what applies.
Related: Fire Alarm Systems
A heat detector responds to temperature rise rather than smoke, which makes it suitable for kitchens and similar environments where smoke detection would produce constant false alarms. It responds later than smoke detection, which is why it is used selectively rather than generally.
Related: Fire Alarm Systems
Yes. A fire alarm is a life safety system and its cabling must be fire-resistant and installed accordingly, so that the system keeps working during the event it exists to warn about. This is one of the areas where cutting corners is both obvious and indefensible.
Related: Fire Alarm Systems
Very possibly. A change of use, an extension or a change in occupancy all affect the fire strategy, and the detection and alarm system follows from that. A system that was adequate for the previous use may not be adequate now — the fire risk assessment should be revisited first.
Related: Fire Alarm Systems
Lighting
Almost always because the dimmer and the LED driver are not compatible. Older dimmers designed for filament lamps frequently do not work properly with LED loads. The fix is matching the dimmer to the fittings — and it is far easier to get right at specification than after installation.
Related: Lighting Systems
Warmer light (around 2700K) suits living rooms and bedrooms; neutral to cooler light (3000–4000K) suits kitchens, bathrooms and workspaces. The important thing is consistency within a space — mixing colour temperatures in one room is the usual reason a newly lit space feels subtly wrong.
Related: Lighting Systems
In premises lit for long hours, generally yes — the reduction in running cost is real and the payback is often short. The caveat is product quality: cheap LED fittings shift colour and fail early, which erodes the saving and means doing the job twice.
Related: Lighting Systems
Usually fewer than are installed. Rooms lit entirely by a grid of downlights tend to feel flat and clinical. A layered approach — general light, task light where you actually do things, and accent light — produces a better result with fewer fittings.
Related: Lighting Systems
Yes. Outdoor fittings need an appropriate ingress protection rating and correctly installed supplies, because they have to survive weather. Paths, steps and entrances benefit most — over-lighting a garden is easy to do and rarely improves it.
Related: Lighting Systems
Motion-triggered lighting at entrances and approach routes, aimed carefully and with sensitivity set sensibly. Badly aimed floodlights that trigger constantly are a nuisance to you and your neighbours, and people stop paying attention to them — which removes the entire benefit.
Related: Lighting Systems
Yes. It is worth deciding early whether control is per-fitting or per-circuit, because that affects the wiring. Retrofitting smart control after the wiring is finished is possible but usually more limited than designing for it from the start.
Related: Lighting Systems
Yes. Bathrooms are divided into zones based on proximity to water, and fittings need an ingress protection rating appropriate to the zone they sit in. This is not a formality — it is the difference between a fitting that is safe in a wet environment and one that is not.
Related: Lighting Systems
Yes, and in retail it is worth treating as a commercial decision rather than a maintenance one. How stock is lit affects how it sells — colour rendering, contrast and the direction light comes from all matter more in a shop than in an office.
Related: Lighting Systems
EV charging
If you have off-street parking, usually yes. The factors that decide it are the incoming supply, the main fuse rating, the condition and capacity of the consumer unit, the earthing arrangement, and the route from the board to where the charge point will go.
Related: EV Charger Installation
For a straightforward domestic installation, typically a single visit — mounting the unit, running a dedicated circuit with appropriate protection, and commissioning it. Where consumer unit work is needed first, that adds time, which is why the assessment happens before anything is ordered.
Related: EV Charger Installation
Often. A charge point needs a dedicated circuit with appropriate protection, and a board with no spare ways or no RCD protection cannot provide it. In older housing this is the most common reason an otherwise simple installation becomes a two-part job.
Related: EV Charger Installation
It is considerably harder. Without an allocated parking space and a viable route from a supply you control, a home charge point often is not practical. Where a block is considering shared charging, that is a project for the building rather than an individual installation.
Related: EV Charger Installation
Because it determines what protection the installation requires. Some supply earthing arrangements need specific measures for a circuit supplying a vehicle outdoors. It is checked as part of the assessment rather than assumed, and it varies between properties on the same street.
Related: EV Charger Installation
One that can schedule charging, respond to tariffs and report usage. The practical benefit is charging when electricity is cheapest, which for most households is where the running-cost saving actually comes from. Some functionality is now expected as standard on new units.
Related: EV Charger Installation
Yes. Where multiple units may be used at the same time, load management is usually needed so that the total demand stays within what the supply can deliver. For commercial installations it is worth planning for future units at the first installation rather than rebuilding later.
Related: EV Charger Installation
Often the existing circuit can be reused, provided the supply and protective devices are adequate for the new unit. That is checked rather than assumed — a faster unit on a circuit sized for the old one is not an upgrade, it is a problem.
Related: EV Charger Installation
Government support changes periodically and eligibility depends on the property and circumstances. [INSERT INFORMATION] — current scheme details and any installer registration required should be confirmed before relying on them.
Related: EV Charger Installation
Yes. Commercial installations raise questions a domestic one does not: how many points, whether they will be used simultaneously, whether load management is needed, access control, and whether usage needs billing or allocating. Those are worth settling before the electrical design.
Related: EV Charger Installation
Areas and coverage
We are based in Enfield and work across London and the surrounding areas. The areas page lists the boroughs we have written pages for — that reflects our published content rather than the limit of our coverage. If your postcode is not listed, call and ask.
Tell us the address when you enquire and we will be clear about anything that affects the price. We do not add unexplained charges after the fact.
Yes — 46 Bradley Road, Enfield, EN3 6ER. Being based in the borough means Enfield site visits are particularly easy to arrange, and it is the area whose housing and commercial stock we know best.
We work across London and the surrounding areas. For anything further afield, call and ask — we would rather tell you honestly whether a job makes sense for us than take on work we cannot service properly.
Yes. For landlords, letting agents and managed property, working across a portfolio is common, and a scheduled programme across sites usually works better than reactive call-outs at each one.
Our own photography
What the work looks like
Our own photographs of completed installations.
Call us
Speak to an electrician
Describe the fault or the job and we will tell you what is involved.
Keep exploring
Where to next
- All electrical services Installation, repairs, CCTV, fire alarms, lighting, EV charging and consumer units.
- Areas we cover Thirty-three London boroughs, each with its own page.
- Guides and advice Fifty practical articles for homeowners, landlords and businesses.
- Project gallery Examples of the work, by type.